Assessment Year | 1994 |
---|---|
Principal Product | Plastic Strapping |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
80,000
ft2
|
Annual Production | 11,000,000
lb
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Virginia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $297,391 | 7,143,025 |
kWh
|
$0.042 |
Natural Gas | $2,100 | 285 |
MMBtu
|
$7.37 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $26,070 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,490 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,766 | $15,710 |
$6,766
162,368
kWh
|
|
02 | 2.4239: Eliminate or reduce compressed air usage | $5,441 | $3,000 |
$5,441
130,715
kWh
|
|
03 | 2.4133: Use most efficient type of electric motors | $4,776 | $8,261 |
$4,776
114,889
kWh
|
|
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,197 | $3,440 |
$3,197
76,788
kWh
|
|
05 | 2.6231: Utilize controls to operate equipment only when needed | $4,076 | $140 |
$4,076
97,890
kWh
|
|
06 | 2.6231: Utilize controls to operate equipment only when needed | $1,814 | $860 |
$1,814
43,669
kWh
|
|
TOTAL RECOMMENDED | $26,070 | $31,411 |
$26,070
626,319
kWh
|
||
TOTAL IMPLEMENTED | $17,490 | $14,841 |
$17,490
420,282
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs