| Assessment Year | 2000 |
|---|---|
| Principal Product | metal sanitary ware |
| NAICS |
n/a
|
| SIC | 3431: Enameled Iron and Metal Sanitary Ware |
| Sales Range | $10 M to 50M |
| # of Employees | 110 |
| Plant Area |
80,000
ft2
|
| Annual Production | 45,000
pieces
|
| Production Hrs. Annual | 2,600
hrs
|
| Location (State) | Nevada |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $40,501 | 971,000 |
kWh
|
$0.042 |
| Electricity Demand | $29,251 | 3,152 |
kW-mo/yr
|
$9.28 |
| Electricity Fees | $1,926 | - |
|
- |
| Natural Gas | $17,591 | 3,351 |
MMBtu
|
$5.25 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $227,934 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7229: Air condition only space necessary | $32,352 | $17,000 | n/a |
$8,650
208,089
kWh
|
$17,758
-
kW-mo/yr
|
$634 |
$5,310
-
MMBtu
|
- |
| 02 | 2.7135: Install occupancy sensors | $321 | $255 | n/a |
$314
7,620
kWh
|
- | $7 | - | - |
| 03 | 2.2437: Recover waste heat from equipment | $180 | $194 | n/a | - | - | - |
$180
-
MMBtu
|
- |
| 04 | 2.6218: Turn off equipment when not in use | $81 | - | n/a |
$81
2,052
kWh
|
- | - | - | - |
| 05 | 4.446: Automate finishing process | $195,000 | $3,465 | n/a | - | - | - | - | $195,000 |
| TOTAL RECOMMENDED | $227,934 | $20,914 |
$9,045
217,761
kWh
|
$17,758
-
kW-mo/yr
|
$641 |
$5,490
-
MMBtu
|
$195,000 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs