| Assessment Year | 1998 |
|---|---|
| Principal Product | Newspapers |
| NAICS |
n/a
|
| SIC | 2711: Newspapers: Publishing, or Publishing and Printing |
| Sales Range | $5 M to 10M |
| # of Employees | 126 |
| Plant Area |
20,946
ft2
|
| Annual Production | 2,200
ton
|
| Production Hrs. Annual | 6,084
hrs
|
| Location (State) | Nevada |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $23,135 | 554,513 |
kWh
|
$0.042 |
| Electricity Demand | $16,648 | 1,794 |
kW-mo/yr
|
$9.28 |
| Electricity Fees | $1,408 | - |
|
- |
| Natural Gas | $3,340 | 511 |
MMBtu
|
$6.54 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $29,449 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $29,449 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4221: Install compressor air intakes in coolest locations | $242 | $252 |
$172
4,103
kWh
|
$65
-
kW-mo/yr
|
$5 | - | - | |
| 02 | 4.111: Add equipment/ operators to reduce production bottleneck | $25,175 | $82,000 | - | - | - | $25,175 | - | |
| 03 | 3.6192: Use a less expensive method of waste removal | $4,032 | $1,000 | - | - | - | - | $4,032 | |
| TOTAL RECOMMENDED | $29,449 | $83,252 |
$172
4,103
kWh
|
$65
-
kW-mo/yr
|
$5 | $25,175 | $4,032 | ||
| TOTAL IMPLEMENTED | $29,449 | $83,252 |
$172
4,103
kWh
|
$65
-
kW-mo/yr
|
$5 | $25,175 | $4,032 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs