| Assessment Year | 1998 |
|---|---|
| Principal Product | Industrial Absorbent |
| NAICS |
n/a
|
| SIC | 3295: Minerals and Earths, Ground or Otherwise Treated |
| Sales Range | $5 M to 10M |
| # of Employees | 55 |
| Plant Area |
80,000
ft2
|
| Annual Production | 52,440
ton
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Nevada |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $92,734 | 2,214,537 |
kWh
|
$0.042 |
| Electricity Demand | $48,921 | 5,653 |
kW-mo/yr
|
$8.65 |
| Electricity Fees | $791 | - |
|
- |
| Fuel Oil #2 | $27,728 | 16,878 |
MMBtu
|
$1.64 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $439,969 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $75,705 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $1,772 | $2,333 | - | - | $1,772 | - | - | |
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,392 | $1,226 |
$2,441
58,324
kWh
|
$999
-
kW-mo/yr
|
$(-48.0) | - | - | |
| 03 | 2.4133: Use most efficient type of electric motors | $4,937 | $10,398 |
$3,541
84,701
kWh
|
$1,465
-
kW-mo/yr
|
$(-69.0) | - | - | |
| 04 | 4.446: Automate finishing process | $68,996 | $19,100 |
$(-184.0)
(-4,396)
kWh
|
$565
-
kW-mo/yr
|
$(-25.0) | - | $68,640 | |
| 05 | 4.441: Install automatic packing equipment | $358,805 | $198,720 |
$(-655.0)
(-15,533)
kWh
|
$(-10.0)
-
kW-mo/yr
|
$7 | - | $359,463 | |
| 06 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $2,067 | - | - | - | - |
$2,067
-
lb
|
- | |
| TOTAL RECOMMENDED | $439,969 | $231,777 |
$5,143
123,096
kWh
|
$3,019
-
kW-mo/yr
|
$1,637 |
$2,067
-
lb
|
$428,103 | ||
| TOTAL IMPLEMENTED | $75,705 | $31,831 |
$3,357
80,305
kWh
|
$2,030
-
kW-mo/yr
|
$1,678 | - | $68,640 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs