Assessment Year | 1997 |
---|---|
Principal Product | Custom Moulded Plastic Products |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 100 |
Plant Area |
50,000
ft2
|
Annual Production | 850,000
lb
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | Nevada |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $71,325 | 1,594,959 |
kWh
|
$0.045 |
Electricity Demand | $43,621 | 4,883 |
kW-mo/yr
|
$8.93 |
Electricity Fees | $878 | - |
|
- |
Natural Gas | $1,955 | 308 |
MMBtu
|
$6.35 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $57,193 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $45,725 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.2511: Insulate bare equipment | $8,983 | $1,120 |
$6,804
152,110
kWh
|
$2,179
-
kW-mo/yr
|
- | - | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,478 | $300 |
$1,478
33,118
kWh
|
- | - | - | - | |
03 | 2.4133: Use most efficient type of electric motors | $353 | $404 |
$268
6,155
kWh
|
$85
-
kW-mo/yr
|
- | - | - | |
04 | 2.7243: Improve air circulation with destratification fans / other methods | $1,293 | $2,925 |
$(-135.0)
(-2,931)
kWh
|
$(-44.0)
-
kW-mo/yr
|
$1,472
-
MMBtu
|
- | - | |
05 | 2.7447: Install vinyl strip / high speed / air curtain doors | $1,167 | $815 | - | - |
$1,167
-
MMBtu
|
- | - | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $839 | $50 |
$839
18,757
kWh
|
- | - | - | - | |
07 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $8,002 | $250 | - | - | - |
$8,002
-
lb
|
- | |
08 | 3.5313: Increase amount of waste recovered for resale | $78 | - | - | - | - |
$78
-
lb
|
- | |
09 | 4.321: Optimize production lot sizes and inventories | $35,000 | $28,000 | - | - | - | - | $35,000 | |
TOTAL RECOMMENDED | $57,193 | $33,864 |
$9,254
207,209
kWh
|
$2,220
-
kW-mo/yr
|
$2,639
-
MMBtu
|
$8,080
-
lb
|
$35,000 | ||
TOTAL IMPLEMENTED | $45,725 | $29,365 |
$1,478
33,118
kWh
|
- |
$1,167
-
MMBtu
|
$8,080
-
lb
|
$35,000 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Primary Raw Material Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs