Assessment Year | 1996 |
---|---|
Principal Product | Printed Paper Products |
NAICS |
n/a
|
SIC | 2679: Converted Paper and Paperboard Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 90 |
Plant Area |
140,000
ft2
|
Annual Production | 17,000,000
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Nevada |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $88,674 | 2,031,946 |
kWh
|
$0.044 |
Electricity Demand | $48,707 | 5,286 |
kW-mo/yr
|
$9.21 |
Electricity Fees | $3,460 | - |
|
- |
Natural Gas | $21,825 | 4,215 |
MMBtu
|
$5.18 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $16,753 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $11,418 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $90 | $31 |
$66
1,465
kWh
|
$24
-
kW-mo/yr
|
- | - | - | |
02 | 2.4221: Install compressor air intakes in coolest locations | $1,307 | $270 |
$1,307
30,188
kWh
|
- | - | - | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,462 | $200 |
$1,462
33,705
kWh
|
- | - | - | - | |
04 | 2.7243: Improve air circulation with destratification fans / other methods | $4,678 | $11,375 | - | - | - |
$4,678
-
MMBtu
|
- | |
05 | 2.7135: Install occupancy sensors | $245 | $94 |
$245
4,396
kWh
|
- | - | - | - | |
06 | 2.3212: Optimize plant power factor | $657 | $1,760 | - | - | $657 | - | - | |
07 | 2.2447: Heat water with exhaust heat | $5,214 | $3,300 |
$253
5,862
kWh
|
$82
-
kW-mo/yr
|
- |
$4,879
-
MMBtu
|
- | |
08 | 3.5313: Increase amount of waste recovered for resale | $3,100 | - | - | - | - | - |
$3,100
-
lb
|
|
TOTAL RECOMMENDED | $16,753 | $17,030 |
$3,333
75,616
kWh
|
$106
-
kW-mo/yr
|
$657 |
$9,557
-
MMBtu
|
$3,100
-
lb
|
||
TOTAL IMPLEMENTED | $11,418 | $3,895 |
$3,333
75,616
kWh
|
$106
-
kW-mo/yr
|
- |
$4,879
-
MMBtu
|
$3,100
-
lb
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs