Assessment Year | 1996 |
---|---|
Principal Product | Commercial Printing |
NAICS |
n/a
|
SIC | 2752: Commercial Printing, Lithographic |
Sales Range | $10 M to 50M |
# of Employees | 90 |
Plant Area |
n/a
|
Annual Production | 1,000,000
lb
|
Production Hrs. Annual | 8,580
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $172,678 | 2,961,606 |
kWh
|
$0.058 |
Electricity Demand | $54,613 | 7,219 |
kW-mo/yr
|
$7.57 |
Electricity Fees | $528 | - |
|
- |
Natural Gas | $72,826 | 12,387 |
MMBtu
|
$5.88 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $17,307 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,501 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $1,882 | $305 |
$1,882
32,239
kWh
|
- | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,819 | $300 |
$1,819
31,067
kWh
|
- | - | |
03 | 2.7111: Reduce illumination to minimum necessary levels | $9,371 | $1,575 |
$7,492
129,250
kWh
|
$1,879
-
kW-mo/yr
|
- | |
04 | 2.7135: Install occupancy sensors | $3,435 | $556 |
$3,435
58,910
kWh
|
- | - | |
05 | 3.5316: Contract a wood pallet recycling company | $800 | - | - | - | $800 | |
TOTAL RECOMMENDED | $17,307 | $2,736 |
$14,628
251,466
kWh
|
$1,879
-
kW-mo/yr
|
$800 | ||
TOTAL IMPLEMENTED | $4,501 | $605 |
$3,701
63,306
kWh
|
- | $800 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs