| Assessment Year | 1996 |
|---|---|
| Principal Product | Redwood Lumber Products |
| NAICS |
n/a
|
| SIC | 2491: Wood Preserving |
| Sales Range | $5 M to 10M |
| # of Employees | 125 |
| Plant Area |
114,000
ft2
|
| Annual Production | 2,000,000
thousand feet
|
| Production Hrs. Annual | 2,163
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $71,562 | 1,384,232 |
kWh
|
$0.052 |
| Electricity Demand | $62,599 | 8,633 |
kW-mo/yr
|
$7.25 |
| Electricity Fees | $10,778 | - |
|
- |
| Natural Gas | $420 | 36 |
MMBtu
|
$11.67 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $12,365 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $12,365 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $6,744 | $17,568 |
$4,655
47,479
kWh
|
$2,089
-
kW-mo/yr
|
- | |
| 02 | 2.6218: Turn off equipment when not in use | $2,143 | - |
$2,143
41,325
kWh
|
- | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,185 | $200 |
$1,185
22,860
kWh
|
- | - | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $169 | $196 |
$169
2,931
kWh
|
- | - | |
| 05 | 2.4226: Use / purchase optimum sized compressor | $1,008 | $4,000 |
$1,008
19,637
kWh
|
- | - | |
| 06 | 3.5313: Increase amount of waste recovered for resale | $1,116 | - | - | - |
$1,116
-
lb
|
|
| TOTAL RECOMMENDED | $12,365 | $21,964 |
$9,160
134,232
kWh
|
$2,089
-
kW-mo/yr
|
$1,116
-
lb
|
||
| TOTAL IMPLEMENTED | $12,365 | $21,964 |
$9,160
134,232
kWh
|
$2,089
-
kW-mo/yr
|
$1,116
-
lb
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs