| Assessment Year | 1996 |
|---|---|
| Principal Product | Rail Cars |
| NAICS |
n/a
|
| SIC | 3743: Railroad Equipment |
| Sales Range | $50 M to 100M |
| # of Employees | 180 |
| Plant Area |
68,000
ft2
|
| Annual Production | 30
pieces
|
| Production Hrs. Annual | 2,366
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $62,985 | 1,005,862 |
kWh
|
$0.063 |
| Electricity Demand | $23,415 | 3,104 |
kW-mo/yr
|
$7.54 |
| Natural Gas | $22,282 | 3,186 |
MMBtu
|
$6.99 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $8,465 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $5,035 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7144: Install spectral reflectors / delamp | $1,741 | $100 |
$1,131
16,706
kWh
|
$610
-
kW-mo/yr
|
- | - | |
| 02 | 2.7243: Improve air circulation with destratification fans / other methods | $1,689 | $3,250 | - | - |
$1,689
-
MMBtu
|
- | |
| 03 | 2.4221: Install compressor air intakes in coolest locations | $121 | $100 |
$121
1,758
kWh
|
- | - | - | |
| 04 | 3.5313: Increase amount of waste recovered for resale | $4,914 | - | - | - | - |
$4,914
-
lb
|
|
| TOTAL RECOMMENDED | $8,465 | $3,450 |
$1,252
18,464
kWh
|
$610
-
kW-mo/yr
|
$1,689
-
MMBtu
|
$4,914
-
lb
|
||
| TOTAL IMPLEMENTED | $5,035 | $100 |
$121
1,758
kWh
|
- | - |
$4,914
-
lb
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs