| Assessment Year | 1994 |
|---|---|
| Principal Product | Trolling Motors |
| NAICS |
n/a
|
| SIC | 3699: Electrical Machinery, Equipment, and Supplies, Not Elsewhere |
| Sales Range | $10 M to 50M |
| # of Employees | 100 |
| Plant Area |
100,000
ft2
|
| Annual Production | 150,000
pieces
|
| Production Hrs. Annual | 2,000
hrs
|
| Location (State) | Mississippi |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $81,497 | 1,248,535 |
kWh
|
$0.065 |
| Natural Gas | $12,703 | 3,047 |
MMBtu
|
$4.17 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $14,324 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4131: Size electric motors for peak operating efficiency | $5,885 | $1,000 |
$5,885
68,581
kWh
|
- | |
| 02 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $6,252 | $10,100 | - |
$6,252
-
MMBtu
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,373 | $502 |
$1,373
16,413
kWh
|
- | |
| 04 | 2.2437: Recover waste heat from equipment | $428 | $1,000 | - |
$428
-
MMBtu
|
|
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $164 | $116 |
$164
2,052
kWh
|
- | |
| 06 | 2.4133: Use most efficient type of electric motors | $222 | $700 |
$222
2,345
kWh
|
- | |
| TOTAL RECOMMENDED | $14,324 | $13,418 |
$7,644
89,391
kWh
|
$6,680
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs