Assessment Year | 1994 |
---|---|
Principal Product | Trolling Motors |
NAICS |
n/a
|
SIC | 3699: Electrical Machinery, Equipment, and Supplies, Not Elsewhere |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
100,000
ft2
|
Annual Production | 150,000
pieces
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $81,497 | 1,248,535 |
kWh
|
$0.065 |
Natural Gas | $12,703 | 3,047 |
MMBtu
|
$4.17 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $14,324 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4131: Size electric motors for peak operating efficiency | $5,885 | $1,000 |
$5,885
68,581
kWh
|
- | |
02 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $6,252 | $10,100 | - |
$6,252
-
MMBtu
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,373 | $502 |
$1,373
16,413
kWh
|
- | |
04 | 2.2437: Recover waste heat from equipment | $428 | $1,000 | - |
$428
-
MMBtu
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $164 | $116 |
$164
2,052
kWh
|
- | |
06 | 2.4133: Use most efficient type of electric motors | $222 | $700 |
$222
2,345
kWh
|
- | |
TOTAL RECOMMENDED | $14,324 | $13,418 |
$7,644
89,391
kWh
|
$6,680
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs