Assessment Year | 1995 |
---|---|
Principal Product | Motorcycle Parts |
NAICS |
n/a
|
SIC | 3751: Motorcycles, Bicycles, and Parts |
Sales Range | $1 M to 5M |
# of Employees | 110 |
Plant Area |
77,200
ft2
|
Annual Production | 120,000
pieces
|
Production Hrs. Annual | 4,420
hrs
|
Location (State) | Nevada |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $52,004 | 558,617 |
kWh
|
$0.093 |
Natural Gas | $26,063 | 4,380 |
MMBtu
|
$5.95 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,868 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $931 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $640 | $3,211 |
$640
6,155
kWh
|
- | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $291 | - |
$291
3,224
kWh
|
- | |
03 | 2.4221: Install compressor air intakes in coolest locations | $289 | $400 |
$289
2,638
kWh
|
- | |
04 | 2.2511: Insulate bare equipment | $3,702 | $1,741 | - |
$3,702
-
MMBtu
|
|
05 | 2.2511: Insulate bare equipment | $2,946 | $2,937 | - |
$2,946
-
MMBtu
|
|
TOTAL RECOMMENDED | $7,868 | $8,289 |
$1,220
12,017
kWh
|
$6,648
-
MMBtu
|
||
TOTAL IMPLEMENTED | $931 | $3,211 |
$931
9,379
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs