ITAC Assessment: NT0064
ITAC logo
ITAC Assessment: NT0064
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2026
Principal Product Mobile homes manufacturing
NAICS 321991: Manufactured Home (Mobile Home) Manufacturing
SIC 2451: Mobile Homes
Sales Range $50
M
to 100
M
# of Employees 198
Plant Area 123,624
ft2
Annual Production 1,596
units
Production Hrs. Annual 2,091
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $30,621 850,456
kWh
Electricity Demand $45,513 3,894
kW-mo/yr
Electricity Fees $3,993 -
LPG $16,585 1,226
MMBtu
Waste Disposal Costs
Water Usage $1 1
Tgal
TOTAL YEARLY COSTS $96,713
RECOMMENDED SAVINGS* $54,072 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings One-time Revenue or Avoided Cost Savings
01 3.5248: Separate and recycle scrap metal to foundry or for sale $14,892 $27,700 - - - $14,892
02 2.4226: Use / purchase optimum sized compressor $27,586 $10,100 - - - $27,586
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,288 $5,753 $1,147
31,874
kWh
$2,140
-
kW-mo/yr
- -
04 2.8121: Apply for tax-free status for energy purchases $7,003 $5,000 - - $7,003 -
05 2.7221: Lower temperature during the winter season and vice-versa $1,303 - $455
12,636
kWh
$848
-
kW-mo/yr
- -
TOTAL RECOMMENDED $54,072 $48,553 $1,602
44,510
kWh
$2,989
-
kW-mo/yr
$7,003 $42,478
TOTAL IMPLEMENTED - - - - - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs