ITAC Assessment: NL0104
ITAC logo
ITAC Assessment: NL0104
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2025
Principal Product Hydraulic Manifolds
NAICS 332912: Fluid Power Valve and Hose Fitting Manufacturing
SIC 3492: Fluid Power Valves and Hose Fittings
Sales Range $10
M
to 50
M
# of Employees 200
Plant Area 100,000
ft2
Annual Production 477,765
units
Production Hrs. Annual 7,928
hrs
Location (State) North Dakota

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $539,301 13,104,000
kWh
Electricity Demand $289,770 24,468
kW-mo/yr
Electricity Fees $77,527 -
Natural Gas $112,517 23,441
MMBtu
Waste Disposal Costs
Water Usage $56,297 13,177
Tgal
Water Disposal $49,698 13,177
Tgal
Other Liquid (non-haz) $2,461 1
gal
TOTAL YEARLY COSTS $1,127,571
RECOMMENDED SAVINGS* $12,017 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings Ancillary Material Cost Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $5,739 $4,500 $6,559
159,984
kWh
- $(-720.0) $(-100.0)
02 2.3132: Recharge batteries on during off-peak demand periods $3,070 $450 - $3,070
-
kW-mo/yr
- -
03 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,482 $490 $1,032
25,157
kWh
$450
-
kW-mo/yr
- -
04 2.4221: Install compressor air intakes in coolest locations $1,235 $500 $1,235
30,118
kWh
- - -
05 2.7142: Utilize higher efficiency lamps and/or ballasts $365 $656 $91
2,207
kWh
$36
-
kW-mo/yr
$239 -
06 2.7135: Install occupancy sensors $126 $239 $126
3,065
kWh
- - -
TOTAL RECOMMENDED $12,017 $6,835 $9,043
220,531
kWh
$3,556
-
kW-mo/yr
$(-481.0) $(-100.0)
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs