Assessment Year | 2023 |
---|---|
Principal Product | Snack Nuts |
NAICS | 311919: Other Snack Food Manufacturing |
SIC | 2068: Salted and Roasted Nuts and Seeds |
Sales Range | $10 M to 50M |
# of Employees | 120 |
Plant Area |
170,800
ft2
|
Annual Production | 18,000,000
units
|
Production Hrs. Annual | 2,600
hrs
|
Location (State) | Nebraska |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $100,668 | 1,548,738 |
kWh
|
$0.065 | |
Electricity Demand | $33,679 | 6,260 |
kW-mo/yr
|
$5.38 | |
Electricity Fees | $6,583 | - |
|
- | |
Natural Gas | $71,903 | 8,726 |
MMBtu
|
$8.24 | |
Waste Disposal Costs | |||||
Water Usage | $3,723 | 1,232 |
Tgal
|
$3.02 | |
Water Disposal | $7,562 | 1,232 |
Tgal
|
$6.14 | |
TOTAL YEARLY COSTS | $224,118 | ||||
RECOMMENDED SAVINGS* | $62,240 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 4.212: Adopt in-house material generation | $50,849 | $76,500 |
$(-2,755.0)
(-42,394)
kWh
|
$(-2,028.0)
-
kW-mo/yr
|
- | $55,632 | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,711 | $26,296 |
$5,228
80,379
kWh
|
$1,345
-
kW-mo/yr
|
$138 | - | |
03 | 2.7243: Improve air circulation with destratification fans / other methods | $3,403 | $10,178 |
$3,297
50,726
kWh
|
$106
-
kW-mo/yr
|
- | - | |
04 | 2.8114: Change rate schedules or other changes in utility service | $808 | $25 | - | - | - | $808 | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $469 | $525 |
$368
5,651
kWh
|
$84
-
kW-mo/yr
|
$17 | - | |
TOTAL RECOMMENDED | $62,240 | $113,524 |
$6,138
94,362
kWh
|
$(-493.0)
-
kW-mo/yr
|
$155 | $56,440 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs