Assessment Year 2023
Principal Product Drywall Components
NAICS 332311: Prefabricated Metal Building and Component Manufacturing
SIC 3448: Prefabricated Metal Buildings and Components
Sales Range $50
M
to 100
M
# of Employees 120
Plant Area 140,000
ft2
Annual Production 166,400
thousand feet
Production Hrs. Annual 6,000
hrs
Location (State) Nebraska

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $111,394 1,774,080
kWh
Electricity Demand $28,234 5,041
kW-mo/yr
Electricity Fees $5,019 -
Natural Gas $11,273 1,292
MMBtu
Waste Disposal Costs
Water Usage $5,461 1,328
Tgal
Water Disposal $1,108 476
Tgal
TOTAL YEARLY COSTS $162,490
RECOMMENDED SAVINGS* $530,352 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $519,239

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings Ancillary Material Cost Savings Increase in Production Savings
01 2.4322: Use or replace with energy efficient substitutes $497,815 $199,200 $5,339
86,114
kWh
$1,655
-
kW-mo/yr
- - $490,821
02 2.7243: Improve air circulation with destratification fans / other methods $15,605 $20,000 $513
8,220
kWh
$92
-
kW-mo/yr
- - $15,000
03 2.4224: Upgrade controls on compressors $7,826 $12,000 $6,628
106,911
kWh
$1,198
-
kW-mo/yr
- - -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $5,819 $5,000 $6,559
105,792
kWh
- $(-640.0) $(-100.0) -
05 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $2,139 $3,320 $2,139
34,500
kWh
- - - -
06 2.7211: Clean and maintain refrigerant condensers and towers $937 $1,210 $937
15,119
kWh
- - - -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $157 $225 $59
946
kWh
$7
-
kW-mo/yr
$91 - -
08 2.7134: Use photocell controls $54 $57 $54
868
kWh
- - - -
TOTAL RECOMMENDED $530,352 $241,012 $22,228
358,470
kWh
$2,952
-
kW-mo/yr
$(-549.0) $(-100.0) $505,821
TOTAL IMPLEMENTED $519,239 $224,200 $12,411
200,126
kWh
$1,747
-
kW-mo/yr
$(-640.0) $(-100.0) $505,821
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings Ancillary Material Cost Savings Increase in Production Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs