Assessment Year | 2020 |
---|---|
Principal Product | Trailers |
NAICS | 336212: Truck Trailer Manufacturing |
SIC | 3715: Truck Trailers |
Sales Range | $50 M to 100M |
# of Employees | 245 |
Plant Area |
256,750
ft2
|
Annual Production | 8,000
units
|
Production Hrs. Annual | 2,320
hrs
|
Location (State) | Nebraska |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $150,234 | 2,933,304 |
kWh
|
$0.051 | |
Electricity Demand | $216,672 | 10,827 |
kW-mo/yr
|
$20.01 | |
Electricity Fees | $361 | - |
|
- | |
Natural Gas | $121,038 | 18,587 |
MMBtu
|
$6.51 | |
Waste Disposal Costs | |||||
Water Usage | $4,533 | 1,210 |
Tgal
|
$3.75 | |
Water Disposal | $3,631 | 1,210 |
Tgal
|
$3.00 | |
TOTAL YEARLY COSTS | $496,469 | ||||
RECOMMENDED SAVINGS* | $59,749 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $22,245 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Water Disposal Savings | Personnel Changes Savings | Primary Raw Material Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $27,083 | $43,749 | - | - | $27,083 | - | - | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $19,291 | $28,235 |
$6,073
119,086
kWh
|
$12,308
-
kW-mo/yr
|
- | - | $910 | - | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,662 | $4,000 |
$5,329
104,495
kWh
|
- | - | - | $(-1,417.0) | $(-250.0) | - | |
04 | 2.8114: Change rate schedules or other changes in utility service | $3,390 | $90 | - | - | - | - | - | - | $3,390 | |
05 | 2.8117: Install sub-metering equipment | $2,954 | $354 | - | - | - |
$2,954
-
Tgal
|
- | - | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $1,894 | $2,550 |
$1,894
37,145
kWh
|
- | - | - | - | - | - | |
07 | 2.2511: Insulate bare equipment | $1,475 | $460 |
$374
7,339
kWh
|
$1,101
-
kW-mo/yr
|
- | - | - | - | - | |
TOTAL RECOMMENDED | $59,749 | $79,438 |
$13,670
268,065
kWh
|
$13,409
-
kW-mo/yr
|
$27,083 |
$2,954
-
Tgal
|
$(-507.0) | $(-250.0) | $3,390 | ||
TOTAL IMPLEMENTED | $22,245 | $28,589 |
$6,073
119,086
kWh
|
$12,308
-
kW-mo/yr
|
- |
$2,954
-
Tgal
|
$910 | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Water Disposal Savings | Personnel Changes Savings | Primary Raw Material Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs