Assessment Year | 2020 |
---|---|
Principal Product | Instruments, Analysis Software, and Reagents |
NAICS | 334519: Other Measuring and Controlling Device Manufacturing |
SIC | 3829: Measuring and Controlling Devices, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 300 |
Plant Area |
200,000
ft2
|
Annual Production | 2,000,000
units
|
Production Hrs. Annual | 2,550
hrs
|
Location (State) | Nebraska |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $165,886 | 3,832,127 |
kWh
|
$0.043 | |
Electricity Demand | $74,153 | 9,262 |
kW-mo/yr
|
$8.01 | |
Electricity Fees | $46,334 | - |
|
- | |
Natural Gas | $54,490 | 7,657 |
MMBtu
|
$7.12 | |
Waste Disposal Costs | |||||
Water Usage | $8,488 | 3,821 |
Tgal
|
$2.22 | |
Water Disposal | $7,520 | 2,669 |
Tgal
|
$2.82 | |
TOTAL YEARLY COSTS | $356,871 | ||||
RECOMMENDED SAVINGS* | $15,030 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $14,052 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $10,951 | $29,928 |
$5,859
135,354
kWh
|
$5,091
-
kW-mo/yr
|
- | - | - | |
02 | 2.7232: Replace existing hvac unit with high efficiency model | $1,983 | $20 |
$955
22,050
kWh
|
$2,102
-
kW-mo/yr
|
$(-1,074.0)
-
MMBtu
|
- | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,007 | $1,000 |
$1,187
27,426
kWh
|
- | - | $(-160.0) | $(-20.0) | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $693 | $1,400 |
$693
16,017
kWh
|
- | - | - | - | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $285 | $20 |
$285
6,588
kWh
|
- | - | - | - | |
06 | 2.6231: Utilize controls to operate equipment only when needed | $111 | $50 |
$111
2,574
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $15,030 | $32,418 |
$9,090
210,009
kWh
|
$7,193
-
kW-mo/yr
|
$(-1,074.0)
-
MMBtu
|
$(-160.0) | $(-20.0) | ||
TOTAL IMPLEMENTED | $14,052 | $30,998 |
$8,112
187,404
kWh
|
$7,193
-
kW-mo/yr
|
$(-1,074.0)
-
MMBtu
|
$(-160.0) | $(-20.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs