| Assessment Year | 2017 | 
|---|---|
| Principal Product | Injection Molded Plastics | 
| NAICS | 326199: All Other Plastics Product Manufacturing | 
| SIC | 3089: Plastics Products, Not Elsewhere Classified | 
| Sales Range | $10 M  to 50M  | 
    
| # of Employees | 120 | 
| Plant Area | 
                            80,000
                 
ft2
 
                     | 
    
| Annual Production | 612,500,000
             
units
 
         | 
    
| Production Hrs. Annual | 8,760
             
hrs
 
         | 
    
| Location (State) | Nebraska | 
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $317,795 | 12,400,000 | 
             
kWh
 
         | 
        $0.026 | |
| Electricity Demand | $506,923 | 24,775 | 
             
kW-mo/yr
 
         | 
        $20.46 | |
| Electricity Fees | $45,156 | - | 
             | 
        - | |
| Waste Disposal Costs | |||||
| Water Usage | $8,934 | 799,600 | 
             
Tgal
 
         | 
        $0.011 | |
| Water Disposal | $13,408 | 742 | 
             
Tgal
 
         | 
        $18.08 | |
| TOTAL YEARLY COSTS | $892,217 | ||||
| RECOMMENDED SAVINGS* | $22,794 | 
             See individual recommendations below 
            *Non-energy impacts included in savings.
         | 
    |||
| IMPLEMENTED SAVINGS* | $22,534 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | 
|---|---|---|---|---|---|---|---|
| 01 | 2.7261: Install timers and/or thermostats | $9,200 | $1,630 | 
                        $9,200
                                                     323,000
                                 
                                            
kWh
 
                             | 
                                                                                - | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,430 | $12,500 | 
                        $3,072
                                                     120,000
                                 
                                            
kWh
 
                             | 
                                                                                
                        $4,358
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,100 | - | 
                        $4,700
                                                     183,000
                                 
                                            
kWh
 
                             | 
                                                                                - | $(-600.0) | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,804 | $2,500 | 
                        $553
                                                     21,580
                                 
                                            
kWh
 
                             | 
                                                                                
                        $1,251
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                - | |
| 05 | 2.7135: Install occupancy sensors | $260 | $225 | 
                        $260
                                                     10,156
                                 
                                            
kWh
 
                             | 
                                                                                - | - | |
| TOTAL RECOMMENDED | $22,794 | $16,855 | 
                        $17,785
                                                     657,736
                                 
                                            
kWh
 
                             | 
                                                                                
                        $5,609
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                $(-600.0) | ||
| TOTAL IMPLEMENTED | $22,534 | $16,630 | 
                        $17,525
                                                     647,580
                                 
                                            
kWh
 
                             | 
                                                                                
                        $5,609
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                $(-600.0) | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs