Assessment Year | 2000 |
---|---|
Principal Product | Laminated Wood Products |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 85 |
Plant Area |
178,000
ft2
|
Annual Production | 6,400
thousand feet
|
Production Hrs. Annual | 3,640
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $69,152 | 1,465,709 |
kWh
|
$0.047 |
Electricity Demand | $39,100 | 9,161 |
kW-mo/yr
|
$4.27 |
Electricity Fees | $3,656 | - |
|
- |
Natural Gas | $20,283 | 3,663 |
MMBtu
|
$5.54 |
LPG | $13,056 | 1,266 |
MMBtu
|
$10.31 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $11,269 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $897 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | LPG Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.8226: Increase efficiency of trucks | $3,969 | $28,000 |
$(-1,066.0)
(-22,567)
kWh
|
$(-320.0)
-
kW-mo/yr
|
- |
$(-7,701.0)
-
MMBtu
|
$13,056
-
MMBtu
|
- | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $897 | $120 |
$897
19,050
kWh
|
- | - | - | - | - | - | |
03 | 2.2437: Recover waste heat from equipment | $883 | $500 | - | - | - |
$883
-
MMBtu
|
- | - | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $430 | $400 |
$329
7,327
kWh
|
$101
-
kW-mo/yr
|
- | - | - | - | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $271 | $400 |
$113
2,345
kWh
|
$14
-
kW-mo/yr
|
- | - | - | $70 | $74 | |
06 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $216 | $200 |
$194
4,103
kWh
|
$118
-
kW-mo/yr
|
- |
$(-96.0)
-
MMBtu
|
- | - | - | |
07 | 2.8121: Apply for tax-free status for energy purchases | $3,656 | $250 | - | - | $3,656 | - | - | - | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $332 | $1,000 |
$231
4,982
kWh
|
$101
-
kW-mo/yr
|
- | - | - | - | - | |
09 | 2.4221: Install compressor air intakes in coolest locations | $187 | $350 |
$130
2,638
kWh
|
$57
-
kW-mo/yr
|
- | - | - | - | - | |
10 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $428 | $2,569 |
$292
6,155
kWh
|
$136
-
kW-mo/yr
|
- | - | - | - | - | |
TOTAL RECOMMENDED | $11,269 | $33,789 |
$1,120
24,033
kWh
|
$207
-
kW-mo/yr
|
$3,656 |
$(-6,914.0)
-
MMBtu
|
$13,056
-
MMBtu
|
$70 | $74 | ||
TOTAL IMPLEMENTED | $897 | $120 |
$897
19,050
kWh
|
- | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | LPG Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs