ITAC Assessment: ND0357
ITAC logo
ITAC Assessment: ND0357
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2000
Principal Product Plywood
NAICS
n/a
SIC 3212:
Sales Range $50
M
to 100
M
# of Employees 280
Plant Area 610,500
ft2
Annual Production 180,000,000
thousand feet
Production Hrs. Annual 2,340
hrs
Location (State) Indiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $226,158 4,336,460
kWh
Electricity Demand $108,612 13,302
kW-mo/yr
Electricity Fees $29,137 -
Natural Gas $81,078 16,669
MMBtu
LPG $56,845 6,271
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $66,380 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $20,326

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings LPG Savings Personnel Changes Savings Ancillary Material Cost Savings
01 2.8114: Change rate schedules or other changes in utility service $18,819 $250 - - $18,819 - - - -
02 2.8121: Apply for tax-free status for energy purchases $10,318 $250 - - $10,318 - - - -
03 2.8226: Increase efficiency of trucks $27,235 $105,000 $(-1,323.0)
(-21,395)
kWh
$(-381.0)
-
kW-mo/yr
- $(-27,906.0)
-
MMBtu
$56,845
-
MMBtu
- -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $2,935 $8,986 $2,164
27,550
kWh
$771
-
kW-mo/yr
- - - - -
05 2.7135: Install occupancy sensors $969 $600 $913
9,965
kWh
$56
-
kW-mo/yr
- - - - -
06 2.7142: Utilize higher efficiency lamps and/or ballasts $769 $1,285 $390
6,155
kWh
$72
-
kW-mo/yr
- - - $219 $88
07 2.7111: Reduce illumination to minimum necessary levels $4,338 $420 $1,505
24,326
kWh
$2,833
-
kW-mo/yr
- - - - -
08 2.4221: Install compressor air intakes in coolest locations $997 $750 $767
10,258
kWh
$230
-
kW-mo/yr
- - - - -
TOTAL RECOMMENDED $66,380 $117,541 $4,416
56,859
kWh
$3,581
-
kW-mo/yr
$29,137 $(-27,906.0)
-
MMBtu
$56,845
-
MMBtu
$219 $88
TOTAL IMPLEMENTED $20,326 $12,291 $5,739
78,254
kWh
$3,962
-
kW-mo/yr
$10,318 - - $219 $88
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings LPG Savings Personnel Changes Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs