Assessment Year 2000
Principal Product Fiber Board
NAICS
n/a
SIC 2631: Paperboard Mills
Sales Range $10
M
to 50
M
# of Employees 75
Plant Area 160,000
ft2
Annual Production 5,000
thousand feet
Production Hrs. Annual 2,210
hrs
Location (State) Michigan

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $117,963 2,283,998
kWh
Electricity Demand $19,511 6,155
kW-mo/yr
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $6,459 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $2,882

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Personnel Changes Savings Administrative Changes Savings Ancillary Material Cost Savings One-time Revenue or Avoided Cost Savings
01 2.4226: Use / purchase optimum sized compressor $386 - $386
7,620
kWh
- - - - - -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $587 $590 $179
3,517
kWh
$15
-
kW-mo/yr
- $270 - $123 -
03 2.7134: Use photocell controls $124 $350 $93
1,758
kWh
$31
-
kW-mo/yr
- - - - -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $862 $6,560 $649
12,603
kWh
$213
-
kW-mo/yr
- - - - -
05 2.2628: Utilize a less expensive cooling method $913 - $442
8,499
kWh
$221
-
kW-mo/yr
- - $250 - -
06 4.425: Eliminate/reduce redundant inspections $134 - - - - $134 - - -
07 2.3511: Use plant owned transformers or lease transformers $2,211 $200 - - $(-3,585.0) - - - $5,796
08 2.8114: Change rate schedules or other changes in utility service $1,242 $250 - - $1,242 - - - -
TOTAL RECOMMENDED $6,459 $7,950 $1,749
33,997
kWh
$480
-
kW-mo/yr
$(-2,343.0) $404 $250 $123 $5,796
TOTAL IMPLEMENTED $2,882 $7,150 $1,656
32,239
kWh
$449
-
kW-mo/yr
- $404 $250 $123 -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Personnel Changes Savings Administrative Changes Savings Ancillary Material Cost Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs