| Assessment Year | 1999 |
|---|---|
| Principal Product | Vitreous china plumbing fixtures |
| NAICS |
n/a
|
| SIC | 3261: Vitreous China Plumbing Fixtures and China and Earthenware Fittings and Bathroom Accessories |
| Sales Range | $10 M to 50M |
| # of Employees | 203 |
| Plant Area |
500,000
ft2
|
| Annual Production | 1,000,000
pieces
|
| Production Hrs. Annual | 4,420
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $140,795 | 8,621,044 |
kWh
|
$0.016 |
| Electricity Demand | $183,079 | 16,541 |
kW-mo/yr
|
$11.07 |
| Natural Gas | $649,748 | 187,783 |
MMBtu
|
$3.46 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $13,487 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $6,942 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7111: Reduce illumination to minimum necessary levels | $2,688 | $750 |
$979
56,565
kWh
|
$1,709
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,197 | $7,544 |
$1,112
64,185
kWh
|
$1,942
-
kW-mo/yr
|
- | $(-20.0) | $163 | |
| 03 | 2.7124: Make a practice of turning off lights when not needed | $117 | $40 |
$27
1,465
kWh
|
$90
-
kW-mo/yr
|
- | - | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $(-61.0) | $1,560 |
$102
5,862
kWh
|
$90
-
kW-mo/yr
|
- | $(-463.0) | $210 | |
| 05 | 2.4221: Install compressor air intakes in coolest locations | $2,668 | $500 |
$733
42,204
kWh
|
$1,935
-
kW-mo/yr
|
- | - | - | |
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,580 | $480 |
$1,580
91,149
kWh
|
- | - | - | - | |
| 07 | 2.2437: Recover waste heat from equipment | $2,577 | $1,200 | - | - |
$2,577
-
MMBtu
|
- | - | |
| 08 | 4.611: Begin a practice of predictive / preventative maintenance | $721 | $1,334 | - | - | - | $721 | - | |
| TOTAL RECOMMENDED | $13,487 | $13,408 |
$4,533
261,430
kWh
|
$5,766
-
kW-mo/yr
|
$2,577
-
MMBtu
|
$238 | $373 | ||
| TOTAL IMPLEMENTED | $6,942 | $2,220 |
$2,340
134,818
kWh
|
$2,025
-
kW-mo/yr
|
$2,577
-
MMBtu
|
- | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs