| Assessment Year | 1999 |
|---|---|
| Principal Product | Fire Fighting Nozzles |
| NAICS |
n/a
|
| SIC | 3569: General Industrial Machinery and Equipment, Not Elsewhere |
| Sales Range | $10 M to 50M |
| # of Employees | 100 |
| Plant Area |
80,000
ft2
|
| Annual Production | 2,500
pieces
|
| Production Hrs. Annual | 4,160
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $83,953 | 1,331,770 |
kWh
|
$0.063 |
| Electricity Demand | $31,363 | 3,828 |
kW-mo/yr
|
$8.19 |
| Natural Gas | $4,061 | 718 |
MMBtu
|
$5.66 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $48,868 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $40,768 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Water Disposal Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Raw Material Savings |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 4.521: Clear and rent existing space | $40,000 | $18,000 | - | - | - | - | - | $40,000 | - | |
| 02 | 2.4133: Use most efficient type of electric motors | $720 | $7,006 |
$621
5,862
kWh
|
$99
-
kW-mo/yr
|
- | - | - | - | - | |
| 03 | 2.4226: Use / purchase optimum sized compressor | $2,442 | $5,000 |
$2,442
44,549
kWh
|
- | - | - | - | - | - | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $1,236 | $1,500 |
$1,236
21,981
kWh
|
- | - | - | - | - | - | |
| 05 | 2.7111: Reduce illumination to minimum necessary levels | $1,296 | $300 |
$898
16,413
kWh
|
$398
-
kW-mo/yr
|
- | - | - | - | - | |
| 06 | 3.4151: Minimize water usage | $870 | $1,400 | - | - | - |
$870
-
Tgal
|
- | - | - | |
| 07 | 3.4151: Minimize water usage | $878 | $2,300 | - | - | - |
$755
-
Tgal
|
$200 | - | $(-77.0) | |
| 08 | 4.811: Demolish old building to reduce tax and insurance bills | $658 | $250 | - | - | $658 | - | - | - | - | |
| 09 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $587 | $100 |
$587
10,844
kWh
|
- | - | - | - | - | - | |
| 10 | 4.611: Begin a practice of predictive / preventative maintenance | $181 | $390 | - | - | - | - | $181 | - | - | |
| TOTAL RECOMMENDED | $48,868 | $36,246 |
$5,784
99,649
kWh
|
$497
-
kW-mo/yr
|
$658 |
$1,625
-
Tgal
|
$381 | $40,000 | $(-77.0) | ||
| TOTAL IMPLEMENTED | $40,768 | $18,490 |
$587
10,844
kWh
|
- | - | - | $181 | $40,000 | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Water Disposal Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Raw Material Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs