Assessment Year 1999
Principal Product Hang Tabs
NAICS
n/a
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 77
Plant Area 90,000
ft2
Annual Production 800,000,000
pieces
Production Hrs. Annual 2,970
hrs
Location (State) Michigan

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $40,171 1,098,476
kWh
Electricity Demand $72,156 6,560
kW-mo/yr
Natural Gas $7,816 1,716
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $6,385 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $2,637

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Wood Savings Ancillary Material Cost Savings One-time Revenue or Avoided Cost Savings
01 2.4221: Install compressor air intakes in coolest locations $131 - $58
1,758
kWh
$73
-
kW-mo/yr
- - - -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $695 $1,893 $297
8,499
kWh
$398
-
kW-mo/yr
- - - -
03 2.7134: Use photocell controls $303 $600 $133
3,810
kWh
$170
-
kW-mo/yr
- - - -
04 2.7111: Reduce illumination to minimum necessary levels $737 $255 $497
8,206
kWh
$240
-
kW-mo/yr
- - - -
05 2.7124: Make a practice of turning off lights when not needed $320 $80 $274
3,224
kWh
$46
-
kW-mo/yr
- - - -
06 2.7142: Utilize higher efficiency lamps and/or ballasts $451 $455 $155
4,396
kWh
$66
-
kW-mo/yr
- - $230 -
07 2.6218: Turn off equipment when not in use $100 $153 $100
2,931
kWh
- - - - -
08 2.1311: Replace electrically-operated equipment with fossil fuel equipment $1,251 $1,600 $312
8,792
kWh
$1,188
-
kW-mo/yr
$(-249.0)
-
MMBtu
- - -
09 4.222: Purchase re-conditioned material instead of new $969 $1,376 $249
3,810
kWh
$172
-
kW-mo/yr
- - - $548
10 3.5316: Contract a wood pallet recycling company $1,428 $125 - - - $1,428
-
MMBtu
- -
TOTAL RECOMMENDED $6,385 $6,537 $2,075
45,426
kWh
$2,353
-
kW-mo/yr
$(-249.0)
-
MMBtu
$1,428
-
MMBtu
$230 $548
TOTAL IMPLEMENTED $2,637 $3,283 $1,414
29,893
kWh
$993
-
kW-mo/yr
- - $230 -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Wood Savings Ancillary Material Cost Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs