ITAC Assessment: ND0312
ITAC logo
ITAC Assessment: ND0312
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1998
Principal Product Windows
NAICS
n/a
SIC 2431: Millwork
Sales Range $10
M
to 50
M
# of Employees 200
Plant Area 203,444
ft2
Annual Production 75,000
pieces
Production Hrs. Annual 2,125
hrs
Location (State) Indiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $21,413 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $547

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Disposal Savings Other Liquid (haz) Savings One-time Revenue or Avoided Cost Savings
01 3.4114: Replace city water with recycled water via cooling tower $8,855 $7,500 - - - $8,855
-
Tgal
- -
02 2.7491: Insulate glazing, walls, ceilings, and roofs $3,382 $7,920 - - $3,382
-
MMBtu
- - -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $2,624 $7,151 $1,466
27,843
kWh
$1,158
-
kW-mo/yr
- - - -
04 2.1311: Replace electrically-operated equipment with fossil fuel equipment $2,457 $3,200 $1,401
31,946
kWh
$1,687
-
kW-mo/yr
$(-631.0)
-
MMBtu
- - -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $513 $150 $513
9,672
kWh
- - - - -
06 3.8211: Convert to aqueous cleaning system $1,191 $100 - - - - $1,191
-
gal
-
07 4.811: Demolish old building to reduce tax and insurance bills $1,072 $250 - - - - - $1,072
08 2.4133: Use most efficient type of electric motors $678 $2,967 $453
8,499
kWh
$225
-
kW-mo/yr
- - - -
09 2.4221: Install compressor air intakes in coolest locations $358 $660 $358
6,741
kWh
- - - - -
10 2.7135: Install occupancy sensors $249 $720 $249
4,689
kWh
- - - - -
11 2.6218: Turn off equipment when not in use $34 - $34
586
kWh
- - - - -
TOTAL RECOMMENDED $21,413 $30,618 $4,474
89,976
kWh
$3,070
-
kW-mo/yr
$2,751
-
MMBtu
$8,855
-
Tgal
$1,191
-
gal
$1,072
TOTAL IMPLEMENTED $547 $150 $547
10,258
kWh
- - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Disposal Savings Other Liquid (haz) Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs