Assessment Year | 1998 |
---|---|
Principal Product | Windows |
NAICS |
n/a
|
SIC | 2431: Millwork |
Sales Range | $10 M to 50M |
# of Employees | 200 |
Plant Area |
203,444
ft2
|
Annual Production | 75,000
pieces
|
Production Hrs. Annual | 2,125
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $21,413 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $547 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Other Liquid (haz) Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 3.4114: Replace city water with recycled water via cooling tower | $8,855 | $7,500 | - | - | - |
$8,855
-
Tgal
|
- | - | |
02 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $3,382 | $7,920 | - | - |
$3,382
-
MMBtu
|
- | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,624 | $7,151 |
$1,466
27,843
kWh
|
$1,158
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $2,457 | $3,200 |
$1,401
31,946
kWh
|
$1,687
-
kW-mo/yr
|
$(-631.0)
-
MMBtu
|
- | - | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $513 | $150 |
$513
9,672
kWh
|
- | - | - | - | - | |
06 | 3.8211: Convert to aqueous cleaning system | $1,191 | $100 | - | - | - | - |
$1,191
-
gal
|
- | |
07 | 4.811: Demolish old building to reduce tax and insurance bills | $1,072 | $250 | - | - | - | - | - | $1,072 | |
08 | 2.4133: Use most efficient type of electric motors | $678 | $2,967 |
$453
8,499
kWh
|
$225
-
kW-mo/yr
|
- | - | - | - | |
09 | 2.4221: Install compressor air intakes in coolest locations | $358 | $660 |
$358
6,741
kWh
|
- | - | - | - | - | |
10 | 2.7135: Install occupancy sensors | $249 | $720 |
$249
4,689
kWh
|
- | - | - | - | - | |
11 | 2.6218: Turn off equipment when not in use | $34 | - |
$34
586
kWh
|
- | - | - | - | - | |
TOTAL RECOMMENDED | $21,413 | $30,618 |
$4,474
89,976
kWh
|
$3,070
-
kW-mo/yr
|
$2,751
-
MMBtu
|
$8,855
-
Tgal
|
$1,191
-
gal
|
$1,072 | ||
TOTAL IMPLEMENTED | $547 | $150 |
$547
10,258
kWh
|
- | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Other Liquid (haz) Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs