| Assessment Year | 1998 |
|---|---|
| Principal Product | lawn vacuum attachments |
| NAICS |
n/a
|
| SIC | 3524: Lawn and Garden Tractors and Home Lawn and Garden Equipment |
| Sales Range | $5 M to 10M |
| # of Employees | 38 |
| Plant Area |
40,000
ft2
|
| Annual Production | 942,000
lb
|
| Production Hrs. Annual | 2,200
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $15,342 | 213,072 |
kWh
|
$0.072 |
| Other Gas | $13,998 | 16,378 |
MMBtu
|
$0.85 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $36,397 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $33,379 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Gas Savings | Other Liquid (haz) Savings | Administrative Changes Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 4.322: Eliminate old stock and modify inventory control | $32,850 | $11,000 | - | - | - | - | - | $32,850 | |
| 02 | 2.4133: Use most efficient type of electric motors | $1,737 | $3,860 |
$1,168
16,120
kWh
|
$569
-
kW-mo/yr
|
- | - | - | - | |
| 03 | 2.7447: Install vinyl strip / high speed / air curtain doors | $882 | $280 | - | - |
$882
-
MMBtu
|
- | - | - | |
| 04 | 3.8221: Use alternatives for acids / alkaline (water, steam, abrasive) | $213 | $50 | - | - | - |
$213
-
gal
|
- | - | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $214 | $150 |
$214
5,862
kWh
|
- | - | - | - | - | |
| 06 | 4.821: Pay bills on time to avoid late fees | $186 | - | - | - | - | - | $186 | - | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $148 | $330 |
$148
1,465
kWh
|
- | - | - | - | - | |
| 08 | 2.7122: Disconnect ballasts | $134 | $311 |
$134
1,758
kWh
|
- | - | - | - | - | |
| 09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $19 | $6 |
$19
293
kWh
|
- | - | - | - | - | |
| 10 | 2.6218: Turn off equipment when not in use | $14 | $40 |
$14
293
kWh
|
- | - | - | - | - | |
| TOTAL RECOMMENDED | $36,397 | $16,027 |
$1,697
25,791
kWh
|
$569
-
kW-mo/yr
|
$882
-
MMBtu
|
$213
-
gal
|
$186 | $32,850 | ||
| TOTAL IMPLEMENTED | $33,379 | $11,837 |
$529
9,671
kWh
|
- | - | - | - | $32,850 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Gas Savings | Other Liquid (haz) Savings | Administrative Changes Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs