Assessment Year | 1998 |
---|---|
Principal Product | Orthopedic Instruments |
NAICS |
n/a
|
SIC | 3841: Surgical and Medical Instruments and Apparatus |
Sales Range | $10 M to 50M |
# of Employees | 202 |
Plant Area |
51,000
ft2
|
Annual Production | 77,000
lb
|
Production Hrs. Annual | 7,344
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $222,457 | 4,183,763 |
kWh
|
$0.053 |
Electricity Demand | $81,508 | 7,858 |
kW-mo/yr
|
$10.37 |
Electricity Fees | $(-51,171.0) | - |
|
- |
Natural Gas | $9,814 | 1,846 |
MMBtu
|
$5.32 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $15,492 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $15,492 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $1,922 | $2,510 |
$1,457
27,550
kWh
|
$465
-
kW-mo/yr
|
- | - | - | |
02 | 2.2511: Insulate bare equipment | $2,468 | $338 | - | - | - |
$2,468
-
MMBtu
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,452 | $6,303 |
$1,142
21,395
kWh
|
$1,310
-
kW-mo/yr
|
- | - | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,679 | $80 |
$1,479
27,843
kWh
|
$200
-
kW-mo/yr
|
- | - | - | |
05 | 2.4221: Install compressor air intakes in coolest locations | $1,312 | $950 |
$1,168
21,981
kWh
|
$144
-
kW-mo/yr
|
- | - | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $911 | $900 |
$420
7,913
kWh
|
$65
-
kW-mo/yr
|
- | - | $426 | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $301 | $208 |
$157
4,396
kWh
|
$105
-
kW-mo/yr
|
- | - | $39 | |
08 | 2.6218: Turn off equipment when not in use | $96 | - |
$96
1,758
kWh
|
- | - | - | - | |
09 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $59 | $350 | - | - | $59 | - | - | |
10 | 2.3212: Optimize plant power factor | $4,292 | $9,475 | - | - | $4,292 | - | - | |
TOTAL RECOMMENDED | $15,492 | $21,114 |
$5,919
112,836
kWh
|
$2,289
-
kW-mo/yr
|
$4,351 |
$2,468
-
MMBtu
|
$465 | ||
TOTAL IMPLEMENTED | $15,492 | $21,114 |
$5,919
112,836
kWh
|
$2,289
-
kW-mo/yr
|
$4,351 |
$2,468
-
MMBtu
|
$465 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs