Assessment Year 2001
Principal Product Moldings and picture frames
NAICS
n/a
SIC 2431: Millwork
Sales Range $5
M
to 10
M
# of Employees 50
Plant Area 29,000
ft2
Annual Production 3,900
thousand feet
Production Hrs. Annual 6,240
hrs
Location (State) New Hampshire

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $69,899 1,010,700
kWh
Electricity Demand $22,945 2,490
kW-mo/yr
Electricity Fees $2,221 -
LPG $2,352 167
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $5,210 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $3,230

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.7111: Reduce illumination to minimum necessary levels $1,900 - $1,900
22,218
kWh
-
02 2.3212: Optimize plant power factor $1,530 $2,100 - $1,530
-
kW-mo/yr
03 2.4221: Install compressor air intakes in coolest locations $500 $600 $500
6,000
kWh
-
04 2.4231: Reduce the pressure of compressed air to the minimum required $460 - $460
5,363
kWh
-
05 2.6218: Turn off equipment when not in use $450 - $450
4,500
kWh
-
06 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $370 $100 $370
4,300
kWh
-
TOTAL RECOMMENDED $5,210 $2,800 $3,680
42,381
kWh
$1,530
-
kW-mo/yr
TOTAL IMPLEMENTED $3,230 $700 $3,230
37,881
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings