| Assessment Year | 1997 |
|---|---|
| Principal Product | agricultural grain dryers |
| NAICS |
n/a
|
| SIC | 3564: Industrial and Commercial Fans and Blowers and Air Purification Equipment |
| Sales Range | $10 M to 50M |
| # of Employees | 150 |
| Plant Area |
177,000
ft2
|
| Annual Production | 2,000
pieces
|
| Production Hrs. Annual | 4,850
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $128,634 | 2,316,530 |
kWh
|
$0.056 |
| Natural Gas | $74,503 | 17,984 |
MMBtu
|
$4.14 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $18,498 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $2,111 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Other Liquid (non-haz) Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.8114: Change rate schedules or other changes in utility service | $8,615 | $500 | - | - | $8,615 | - | |
| 02 | 2.4133: Use most efficient type of electric motors | $1,081 | $1,292 |
$1,081
18,464
kWh
|
- | - | - | |
| 03 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | $3,450 | $1,000 | - |
$3,450
-
gal
|
- | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,130 | $1,005 |
$1,130
18,171
kWh
|
- | - | - | |
| 05 | 2.4221: Install compressor air intakes in coolest locations | $1,055 | $500 |
$1,055
18,171
kWh
|
- | - | - | |
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $866 | $460 |
$866
14,947
kWh
|
- | - | - | |
| 07 | 2.7135: Install occupancy sensors | $724 | $1,000 |
$724
11,430
kWh
|
- | - | - | |
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $571 | $108 |
$571
7,327
kWh
|
- | - | - | |
| 09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $482 | $910 |
$482
3,810
kWh
|
- | - | - | |
| 10 | 3.5316: Contract a wood pallet recycling company | $360 | - | - | - | - | $360 | |
| 11 | 2.7122: Disconnect ballasts | $92 | $150 |
$92
1,465
kWh
|
- | - | - | |
| 12 | 2.6218: Turn off equipment when not in use | $72 | $50 |
$72
1,172
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $18,498 | $6,975 |
$6,073
94,957
kWh
|
$3,450
-
gal
|
$8,615 | $360 | ||
| TOTAL IMPLEMENTED | $2,111 | $1,952 |
$2,111
36,048
kWh
|
- | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Other Liquid (non-haz) Savings | Administrative Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs