Assessment Year | 1997 |
---|---|
Principal Product | Rotary Steam Joints, Water Joints |
NAICS |
n/a
|
SIC | 3568: Mechanical Power Transmission Equipment, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 165 |
Plant Area |
185,000
ft2
|
Annual Production | 30,000,000
lb
|
Production Hrs. Annual | 4,488
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $45,050 | 1,341,735 |
kWh
|
$0.034 |
Electricity Demand | $41,775 | 4,224 |
kW-mo/yr
|
$9.89 |
Natural Gas | $1,791 | 1,317 |
MMBtu
|
$1.36 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $33,467 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $25,985 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Other Liquid (haz) Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 3.4111: Use closed cycle process to minimize waste water production | $10,296 | $30,000 |
$(-318.0)
(-4,982)
kWh
|
- | - |
$10,614
-
Tgal
|
- | |
02 | 2.4133: Use most efficient type of electric motors | $8,819 | $14,790 |
$8,512
138,335
kWh
|
$307
-
kW-mo/yr
|
- | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,691 | $3,711 |
$4,483
61,254
kWh
|
$208
-
kW-mo/yr
|
- | - | - | |
04 | 2.7135: Install occupancy sensors | $3,281 | $1,200 |
$1,969
55,393
kWh
|
$1,312
-
kW-mo/yr
|
- | - | - | |
05 | 2.7447: Install vinyl strip / high speed / air curtain doors | $2,940 | $3,795 | - | - |
$2,940
-
MMBtu
|
- | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,668 | $360 |
$1,668
26,084
kWh
|
- | - | - | - | |
07 | 2.2437: Recover waste heat from equipment | $662 | $993 | - | - |
$662
-
MMBtu
|
- | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $402 | $660 |
$206
2,931
kWh
|
$196
-
kW-mo/yr
|
- | - | - | |
09 | 2.7145: Install skylights | $325 | $623 | - | - |
$325
-
MMBtu
|
- | - | |
10 | 2.6218: Turn off equipment when not in use | $274 | - |
$165
9,672
kWh
|
$109
-
kW-mo/yr
|
- | - | - | |
11 | 3.8312: Use building materials which require less energy to produce | $109 | $38 | - | - | - | - |
$109
-
gal
|
|
TOTAL RECOMMENDED | $33,467 | $56,170 |
$16,685
288,687
kWh
|
$2,132
-
kW-mo/yr
|
$3,927
-
MMBtu
|
$10,614
-
Tgal
|
$109
-
gal
|
||
TOTAL IMPLEMENTED | $25,985 | $49,559 |
$14,551
223,622
kWh
|
$711
-
kW-mo/yr
|
- |
$10,614
-
Tgal
|
$109
-
gal
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Other Liquid (haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs