| Assessment Year | 1996 |
|---|---|
| Principal Product | Doors |
| NAICS |
n/a
|
| SIC | 2431: Millwork |
| Sales Range | $10 M to 50M |
| # of Employees | 175 |
| Plant Area |
310,000
ft2
|
| Annual Production | 400,000
pieces
|
| Production Hrs. Annual | 3,500
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $257,400 | 4,634,525 |
kWh
|
$0.056 |
| Electricity Demand | $67,487 | 17,085 |
kW-mo/yr
|
$3.95 |
| Electricity Fees | $11,310 | - |
|
- |
| Natural Gas | $75,930 | 17,572 |
MMBtu
|
$4.32 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $43,182 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4221: Install compressor air intakes in coolest locations | $880 | $260 | n/a |
$880
15,826
kWh
|
- | - | - | - |
| 02 | 2.7135: Install occupancy sensors | $719 | $400 | n/a |
$719
12,896
kWh
|
- | - | - | - |
| 03 | 2.6218: Turn off equipment when not in use | $203 | $504 | n/a |
$203
3,517
kWh
|
- | - | - | - |
| 04 | 2.6218: Turn off equipment when not in use | $153 | $40 | n/a |
$153
2,638
kWh
|
- | - | - | - |
| 05 | 2.7134: Use photocell controls | $275 | $600 | n/a |
$275
4,982
kWh
|
- | - | - | - |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,362 | $1,282 | n/a |
$1,089
23,154
kWh
|
$273
-
kW-mo/yr
|
- | - | - |
| 07 | 2.2437: Recover waste heat from equipment | $1,431 | $460 | n/a | - | - |
$1,431
-
MMBtu
|
- | - |
| 08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,635 | $1,000 | n/a |
$4,635
83,529
kWh
|
- | - | - | - |
| 09 | 2.3511: Use plant owned transformers or lease transformers | $29,520 | $100,000 | n/a | - | - | - | - | $29,520 |
| 10 | 2.7447: Install vinyl strip / high speed / air curtain doors | $781 | $1,156 | n/a | - | - |
$781
-
MMBtu
|
- | - |
| 11 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | $3,223 | $200 | n/a | - | - | - |
$3,223
-
gal
|
- |
| TOTAL RECOMMENDED | $43,182 | $105,902 |
$7,954
146,542
kWh
|
$273
-
kW-mo/yr
|
$2,212
-
MMBtu
|
$3,223
-
gal
|
$29,520 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs