ITAC Assessment: ND0256
ITAC logo
ITAC Assessment: ND0256
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1996
Principal Product Aluminum clamps
NAICS
n/a
SIC 3429: Hardware, Not Elsewhere Classified
Sales Range $1
M
to 5
M
# of Employees 45
Plant Area 41,000
ft2
Annual Production 1,500,000
lb
Production Hrs. Annual 2,040
hrs
Location (State) Indiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $30,755 495,604
kWh
Electricity Demand $19,900 2,416
kW-mo/yr
Natural Gas $4,098 786
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $4,793 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $3,288

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Other Liquid (non-haz) Savings Solid Waste (non-haz) Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $163 $597 $99
1,172
kWh
$64
-
kW-mo/yr
- -
02 2.4133: Use most efficient type of electric motors $520 $882 $314
5,569
kWh
$206
-
kW-mo/yr
- -
03 2.6218: Turn off equipment when not in use $117 $57 $117
1,758
kWh
- - -
04 2.7135: Install occupancy sensors $444 $560 $270
4,689
kWh
$174
-
kW-mo/yr
- -
05 2.7135: Install occupancy sensors $564 $1,200 $564
5,862
kWh
- - -
06 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,172 $650 $2,172
22,274
kWh
- - -
07 2.4221: Install compressor air intakes in coolest locations $497 $200 $497
5,275
kWh
- - -
08 3.7214: Reduce or eliminate waste $316 $700 - - $14
-
gal
$302
-
lb
TOTAL RECOMMENDED $4,793 $4,846 $4,033
46,599
kWh
$444
-
kW-mo/yr
$14
-
gal
$302
-
lb
TOTAL IMPLEMENTED $3,288 $2,886 $2,702
30,773
kWh
$270
-
kW-mo/yr
$14
-
gal
$302
-
lb
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Other Liquid (non-haz) Savings Solid Waste (non-haz) Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs