Assessment Year | 1996 |
---|---|
Principal Product | Air Fresheners units |
NAICS |
n/a
|
SIC | 3433: Heating Equipment, Except Electric and Warm Air Furnaces |
Sales Range | $1 M to 5M |
# of Employees | 146 |
Plant Area |
36,000
ft2
|
Annual Production | 49,000,000
pieces
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $86,317 | 1,780,481 |
kWh
|
$0.048 |
Electricity Demand | $19,738 | 3,743 |
kW-mo/yr
|
$5.27 |
Natural Gas | $2,582 | 585 |
MMBtu
|
$4.41 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $56,001 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $140 | $360 |
$112
2,638
kWh
|
$28
-
kW-mo/yr
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $37 | $160 |
$31
586
kWh
|
$6
-
kW-mo/yr
|
- | - | |
03 | 2.3212: Optimize plant power factor | $2,761 | $3,563 | - | - | $2,761 | - | |
04 | 2.7111: Reduce illumination to minimum necessary levels | $2,453 | $1,000 |
$1,959
60,375
kWh
|
$494
-
kW-mo/yr
|
- | - | |
05 | 2.7111: Reduce illumination to minimum necessary levels | $3,165 | $1,000 |
$2,625
50,996
kWh
|
$540
-
kW-mo/yr
|
- | - | |
06 | 2.8121: Apply for tax-free status for energy purchases | $2,950 | $800 | - | - | $2,950 | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,524 | $370 |
$1,215
36,049
kWh
|
$309
-
kW-mo/yr
|
- | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $232 | $279 |
$172
2,638
kWh
|
$60
-
kW-mo/yr
|
- | - | |
09 | 2.6218: Turn off equipment when not in use | $52 | $504 |
$52
1,172
kWh
|
- | - | - | |
10 | 2.6218: Turn off equipment when not in use | $62 | $504 |
$62
879
kWh
|
- | - | - | |
11 | 2.7135: Install occupancy sensors | $457 | $1,000 |
$457
11,137
kWh
|
- | - | - | |
12 | 2.7135: Install occupancy sensors | $1,219 | $1,000 |
$1,219
19,637
kWh
|
- | - | - | |
13 | 2.4221: Install compressor air intakes in coolest locations | $257 | $100 |
$257
6,448
kWh
|
- | - | - | |
14 | 2.4221: Install compressor air intakes in coolest locations | $372 | $100 |
$372
5,862
kWh
|
- | - | - | |
15 | 3.5212: Regrind, reuse, or sell scrap plastic parts | $40,320 | $340 | - | - | - |
$40,320
-
lb
|
|
TOTAL RECOMMENDED | $56,001 | $11,080 |
$8,533
198,417
kWh
|
$1,437
-
kW-mo/yr
|
$5,711 |
$40,320
-
lb
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs