| Assessment Year | 1995 |
|---|---|
| Principal Product | Brass and Aluminum Castings |
| NAICS |
n/a
|
| SIC | 3362: |
| Sales Range | $5 M to 10M |
| # of Employees | 50 |
| Plant Area |
46,000
ft2
|
| Annual Production | 2,400,000
lb
|
| Production Hrs. Annual | 4,212
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $75,029 | 2,187,573 |
kWh
|
$0.034 |
| Natural Gas | $88,777 | 19,692 |
MMBtu
|
$4.51 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $15,773 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $9,113 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4221: Install compressor air intakes in coolest locations | $855 | $80 |
$855
13,482
kWh
|
|
| 02 | 2.3212: Optimize plant power factor | $4,281 | $550 |
$4,281
-
kWh
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,408 | $647 |
$2,408
38,101
kWh
|
|
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,569 | $750 |
$1,569
24,619
kWh
|
|
| 05 | 2.7111: Reduce illumination to minimum necessary levels | $463 | $300 |
$463
7,327
kWh
|
|
| 06 | 2.4133: Use most efficient type of electric motors | $5,638 | $5,480 |
$5,638
88,804
kWh
|
|
| 07 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $559 | $2,200 |
$559
12,309
kWh
|
|
| TOTAL RECOMMENDED | $15,773 | $10,007 |
$15,773
184,642
kWh
|
||
| TOTAL IMPLEMENTED | $9,113 | $2,027 |
$9,113
76,202
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs