Assessment Year 1994
Principal Product steel processing
NAICS
n/a
SIC 3312: Steel Works, Blast Furnaces (Including Coke Ovens), and Rolling Mills
Sales Range $50
M
to 100
M
# of Employees 300
Plant Area 200,000
ft2
Annual Production 576,000
ton
Production Hrs. Annual 7,488
hrs
Location (State) Indiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $431,680 8,320,047
kWh
Natural Gas $87,850 23,092
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $67,152 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.7447: Install vinyl strip / high speed / air curtain doors $23,569 $40,205 - $23,569
-
MMBtu
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $17,930 $2,250 $17,930
345,545
kWh
-
03 2.4133: Use most efficient type of electric motors $12,144 $30,800 $12,144
467,761
kWh
-
04 2.7111: Reduce illumination to minimum necessary levels $7,111 $300 $7,111
137,163
kWh
-
05 2.7135: Install occupancy sensors $3,616 $5,000 $3,616
80,305
kWh
-
06 2.7142: Utilize higher efficiency lamps and/or ballasts $2,413 $1,464 $2,413
46,893
kWh
-
07 2.7142: Utilize higher efficiency lamps and/or ballasts $313 $760 $313
6,155
kWh
-
08 2.7444: Close holes and openings in building such as broken windows $56 $60 - $56
-
MMBtu
TOTAL RECOMMENDED $67,152 $80,839 $43,527
1,083,822
kWh
$23,625
-
MMBtu
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs