| Assessment Year | 1994 |
|---|---|
| Principal Product | Processed steel |
| NAICS |
n/a
|
| SIC | 3312: Steel Works, Blast Furnaces (Including Coke Ovens), and Rolling Mills |
| Sales Range | $50 M to 100M |
| # of Employees | 100 |
| Plant Area |
146,634
ft2
|
| Annual Production | 384,000
ton
|
| Production Hrs. Annual | 7,200
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $514,665 | 9,833,236 |
kWh
|
$0.052 |
| Natural Gas | $225,421 | 51,988 |
MMBtu
|
$4.34 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $36,790 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $21,765 | $33,110 |
$21,765
415,885
kWh
|
- | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,032 | $1,000 |
$6,032
115,182
kWh
|
- | |
| 03 | 2.8121: Apply for tax-free status for energy purchases | $5,000 | $250 | - | $5,000 | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $2,114 | $300 |
$2,114
40,445
kWh
|
- | |
| 05 | 2.7135: Install occupancy sensors | $1,185 | $2,400 |
$1,185
22,567
kWh
|
- | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $368 | $815 |
$368
7,034
kWh
|
- | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $326 | $170 |
$326
6,155
kWh
|
- | |
| TOTAL RECOMMENDED | $36,790 | $38,045 |
$31,790
607,268
kWh
|
$5,000 | ||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs