| Assessment Year | 1994 |
|---|---|
| Principal Product | automotive aluminum wheels |
| NAICS |
n/a
|
| SIC | 3714: Motor Vehicle Parts and Accessories |
| Sales Range | $10 M to 50M |
| # of Employees | 213 |
| Plant Area |
158,000
ft2
|
| Annual Production | 1,100,000
pieces
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $822,880 | 17,287,222 |
kWh
|
$0.048 |
| Natural Gas | $521,587 | 151,953 |
MMBtu
|
$3.43 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $30,993 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $28,932 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4221: Install compressor air intakes in coolest locations | $15,561 | $3,270 |
$15,561
327,081
kWh
|
|
| 02 | 2.4133: Use most efficient type of electric motors | $12,387 | $15,255 |
$12,387
257,620
kWh
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,902 | $1,412 |
$1,902
39,859
kWh
|
|
| 04 | 2.6212: Turn off equipment during breaks, reduce operating time | $984 | - |
$984
20,516
kWh
|
|
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $159 | $420 |
$159
3,224
kWh
|
|
| TOTAL RECOMMENDED | $30,993 | $20,357 |
$30,993
648,300
kWh
|
||
| TOTAL IMPLEMENTED | $28,932 | $18,525 |
$28,932
605,217
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs