| Assessment Year | 1994 |
|---|---|
| Principal Product | Hydraulic Cylinders |
| NAICS |
n/a
|
| SIC | 3593: Fluid Power Cylinders and Actuators |
| Sales Range | $5 M to 10M |
| # of Employees | 100 |
| Plant Area |
100,000
ft2
|
| Annual Production | 8,600
pieces
|
| Production Hrs. Annual | 7,488
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $93,356 | 1,601,700 |
kWh
|
$0.058 |
| Natural Gas | $37,412 | 9,287 |
MMBtu
|
$4.03 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $18,039 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $16,858 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $8,265 | $1,380 |
$8,265
141,852
kWh
|
- | |
| 02 | 2.4133: Use most efficient type of electric motors | $5,718 | $8,060 |
$5,718
98,183
kWh
|
- | |
| 03 | 2.7444: Close holes and openings in building such as broken windows | $766 | $225 | - |
$766
-
MMBtu
|
|
| 04 | 2.7135: Install occupancy sensors | $1,678 | $2,900 |
$1,678
28,722
kWh
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,197 | $1,035 |
$1,197
20,516
kWh
|
- | |
| 06 | 2.7447: Install vinyl strip / high speed / air curtain doors | $182 | $638 | - |
$182
-
MMBtu
|
|
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $233 | $460 |
$233
4,103
kWh
|
- | |
| TOTAL RECOMMENDED | $18,039 | $14,698 |
$17,091
293,376
kWh
|
$948
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $16,858 | $13,375 |
$16,858
289,273
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs