| Assessment Year | 1997 |
|---|---|
| Principal Product | Forming fabric |
| NAICS |
n/a
|
| SIC | 2221: Broadwoven Fabric Mills, Manmade Fiber and Silk |
| Sales Range | $10 M to 50M |
| # of Employees | 120 |
| Plant Area |
160,500
ft2
|
| Annual Production | 754
thousand feet
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $285,497 | 9,406,800 |
kWh
|
$0.030 |
| Electricity Demand | $141,827 | 17,617 |
kW-mo/yr
|
$8.05 |
| Electricity Fees | $10,031 | - |
|
- |
| Natural Gas | $105,399 | 17,847 |
MMBtu
|
$5.91 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $390,407 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Raw Material Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 3.1192: Reduce scrap production | $151,000 | $13,920 | n/a | - | - |
$134,000
-
lb
|
$17,000 | - | - | - |
| 02 | 3.5311: Recover and reuse waste material | $95,500 | $12,800 | n/a |
$(-1,000.0)
(-21,981)
kWh
|
- |
$4,800
-
lb
|
$(-64,300.0) | - | $156,000 | - |
| 03 | 4.421: Modify current incentive program | $59,900 | $10,000 | n/a | - | - | - | - | $(-25,000.0) | - | $84,900 |
| 04 | 4.321: Optimize production lot sizes and inventories | $33,035 | $13,000 | n/a | - | - | - | $5,620 | $25,615 | $1,800 | - |
| 05 | 2.7226: Use computer programs to optimize hvac performance | $30,661 | $92,600 | n/a |
$13,325
444,314
kWh
|
$17,336
-
MMBtu
|
- | - | - | - | - |
| 06 | 2.7226: Use computer programs to optimize hvac performance | $7,685 | $13,600 | n/a |
$7,685
256,155
kWh
|
- | - | - | - | - | - |
| 07 | 3.6192: Use a less expensive method of waste removal | $5,900 | - | n/a | - |
$7,900
-
MMBtu
|
- | $(-2,000.0) | - | - | - |
| 08 | 2.7111: Reduce illumination to minimum necessary levels | $4,530 | $9,800 | n/a |
$4,530
150,938
kWh
|
- | - | - | - | - | - |
| 09 | 2.2437: Recover waste heat from equipment | $2,196 | $4,750 | n/a | - |
$2,196
-
MMBtu
|
- | - | - | - | - |
| TOTAL RECOMMENDED | $390,407 | $170,470 |
$24,540
829,426
kWh
|
$27,432
-
MMBtu
|
$138,800
-
lb
|
$(-43,680.0) | $615 | $157,800 | $84,900 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Raw Material Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs