| Assessment Year | 1993 |
|---|---|
| Principal Product | Steel Forgings and Stampings |
| NAICS |
n/a
|
| SIC | 3312: Steel Works, Blast Furnaces (Including Coke Ovens), and Rolling Mills |
| Sales Range | $1 M to 5M |
| # of Employees | 6 |
| Plant Area |
20,000
ft2
|
| Annual Production | 3,000,000
pieces
|
| Production Hrs. Annual | 2,000
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $32,772 | 333,529 |
kWh
|
$0.098 |
| Natural Gas | $4,584 | 811 |
MMBtu
|
$5.65 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $3,712 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7243: Improve air circulation with destratification fans / other methods | $1,540 | $2,800 | n/a | - |
$1,540
-
MMBtu
|
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,188 | $200 | n/a |
$1,188
12,016
kWh
|
- |
| 03 | 2.4133: Use most efficient type of electric motors | $261 | $283 | n/a |
$261
2,638
kWh
|
- |
| 04 | 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available | $354 | $450 | n/a |
$354
3,517
kWh
|
- |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $172 | $46 | n/a |
$172
1,758
kWh
|
- |
| 06 | 2.4221: Install compressor air intakes in coolest locations | $197 | $350 | n/a |
$197
2,052
kWh
|
- |
| TOTAL RECOMMENDED | $3,712 | $4,129 |
$2,172
21,981
kWh
|
$1,540
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs