| Assessment Year | 2024 |
|---|---|
| Principal Product | coated aluminum and steel sheet |
| NAICS | 332812: Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers |
| SIC | 3479: Coating, Engraving, and Allied Services, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 75 |
| Plant Area |
151,505
ft2
|
| Annual Production | 51,000
ton
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Missouri |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $532,557 | 6,816,819 |
kWh
|
$0.078 | |
| Electricity Demand | $46,160 | 16,101 |
kW-mo/yr
|
$2.87 | |
| Natural Gas | $1,281,847 | 202,615 |
MMBtu
|
$6.33 | |
| Waste Disposal Costs | |||||
| Water Usage | $64,796 | 27,900 |
Tgal
|
$2.32 | |
| TOTAL YEARLY COSTS | $1,925,360 | ||||
| RECOMMENDED SAVINGS* | $28,265 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $23,378 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4239: Eliminate or reduce compressed air usage | $9,335 | $1,200 |
$8,875
113,785
kWh
|
$460
-
kW-mo/yr
|
- | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,322 | $200 |
$1,258
16,131
kWh
|
$64
-
kW-mo/yr
|
- | |
| 03 | 2.7135: Install occupancy sensors | $1,050 | $2,050 |
$1,050
13,471
kWh
|
- | - | |
| 04 | 2.7221: Lower temperature during the winter season and vice-versa | $1,826 | $1,760 |
$1,826
23,420
kWh
|
- | - | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,179 | $320 |
$1,122
14,381
kWh
|
$57
-
kW-mo/yr
|
- | |
| 06 | 2.1233: Analyze flue gas for proper air/fuel ratio | $8,666 | $2,000 | - | - |
$8,666
-
MMBtu
|
|
| 07 | 2.2427: Use waste heat from hot flue gases to preheat incoming fluids | $4,887 | $14,220 | - | - |
$4,887
-
MMBtu
|
|
| TOTAL RECOMMENDED | $28,265 | $21,750 |
$14,131
181,188
kWh
|
$581
-
kW-mo/yr
|
$13,553
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $23,378 | $7,530 |
$14,131
181,188
kWh
|
$581
-
kW-mo/yr
|
$8,666
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs