Assessment Year | 2024 |
---|---|
Principal Product | coated aluminum and steel sheet |
NAICS | 332812: Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers |
SIC | 3479: Coating, Engraving, and Allied Services, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 75 |
Plant Area |
151,505
ft2
|
Annual Production | 51,000
ton
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $532,557 | 6,816,819 |
kWh
|
$0.078 | |
Electricity Demand | $46,160 | 16,101 |
kW-mo/yr
|
$2.87 | |
Natural Gas | $1,281,847 | 202,615 |
MMBtu
|
$6.33 | |
Waste Disposal Costs | |||||
Water Usage | $64,796 | 27,900 |
Tgal
|
$2.32 | |
TOTAL YEARLY COSTS | $1,925,360 | ||||
RECOMMENDED SAVINGS* | $28,265 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4239: Eliminate or reduce compressed air usage | $9,335 | $1,200 |
$8,875
113,785
kWh
|
$460
-
kW-mo/yr
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,322 | $200 |
$1,258
16,131
kWh
|
$64
-
kW-mo/yr
|
- | |
03 | 2.7135: Install occupancy sensors | $1,050 | $2,050 |
$1,050
13,471
kWh
|
- | - | |
04 | 2.7221: Lower temperature during the winter season and vice-versa | $1,826 | $1,760 |
$1,826
23,420
kWh
|
- | - | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,179 | $320 |
$1,122
14,381
kWh
|
$57
-
kW-mo/yr
|
- | |
06 | 2.1233: Analyze flue gas for proper air/fuel ratio | $8,666 | $2,000 | - | - |
$8,666
-
MMBtu
|
|
07 | 2.2427: Use waste heat from hot flue gases to preheat incoming fluids | $4,887 | $14,220 | - | - |
$4,887
-
MMBtu
|
|
TOTAL RECOMMENDED | $28,265 | $21,750 |
$14,131
181,188
kWh
|
$581
-
kW-mo/yr
|
$13,553
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs