Assessment Year | 1993 |
---|---|
Principal Product | Sheet metal fabricator |
NAICS |
n/a
|
SIC | 3444: Sheet Metal Work |
Sales Range | $5 M to 10M |
# of Employees | 77 |
Plant Area |
142,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $86,125 | 1,781,946 |
kWh
|
$0.048 |
Natural Gas | $90,517 | 22,042 |
MMBtu
|
$4.11 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $4,748 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,369 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,842 | $840 |
$1,842
38,101
kWh
|
- | |
02 | 2.7447: Install vinyl strip / high speed / air curtain doors | $1,238 | $675 | - |
$1,238
-
MMBtu
|
|
03 | 2.4133: Use most efficient type of electric motors | $535 | $661 |
$535
11,137
kWh
|
- | |
04 | 2.7447: Install vinyl strip / high speed / air curtain doors | $578 | $1,660 | - |
$578
-
MMBtu
|
|
05 | 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available | $527 | $80 |
$527
13,482
kWh
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $28 | $40 |
$28
586
kWh
|
- | |
TOTAL RECOMMENDED | $4,748 | $3,956 |
$2,932
63,306
kWh
|
$1,816
-
MMBtu
|
||
TOTAL IMPLEMENTED | $2,369 | $920 |
$2,369
51,583
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs