Assessment Year | 1993 |
---|---|
Principal Product | Ammonium Nitrate |
NAICS |
n/a
|
SIC | 2892: Explosives |
Sales Range | $10 M to 50M |
# of Employees | 50 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $913,511 | 15,680,246 |
kWh
|
$0.058 |
Natural Gas | $1,555,144 | 523,994 |
MMBtu
|
$2.97 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $84,065 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $6,683 | $3,575 | n/a |
$6,683
172,040
kWh
|
- |
02 | 2.1233: Analyze flue gas for proper air/fuel ratio | $46,659 | $5,000 | n/a | - |
$46,659
-
MMBtu
|
03 | 2.4221: Install compressor air intakes in coolest locations | $250 | $240 | n/a |
$250
4,396
kWh
|
- |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,058 | $849 | n/a |
$2,058
35,463
kWh
|
- |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,142 | $1,525 | n/a |
$3,142
37,808
kWh
|
- |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $260 | $459 | n/a |
$260
4,396
kWh
|
- |
07 | 2.8123: Pay utility bills on time | $25,013 | - | n/a |
$25,013
-
kWh
|
- |
TOTAL RECOMMENDED | $84,065 | $11,648 |
$37,406
254,103
kWh
|
$46,659
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs