| Assessment Year | 1994 |
|---|---|
| Principal Product | Grey iron ductile castings |
| NAICS |
n/a
|
| SIC | 3321: Gray and Ductile Iron Foundries |
| Sales Range | $5 M to 10M |
| # of Employees | 130 |
| Plant Area |
145,000
ft2
|
| Annual Production | 4,000
ton
|
| Production Hrs. Annual | 4,680
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $659,826 | 9,992,673 |
kWh
|
$0.066 |
| Natural Gas | $122,899 | 33,330 |
MMBtu
|
$3.69 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $24,167 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $22,806 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $20,977 | $2,160 |
$20,977
317,702
kWh
|
|
| 02 | 2.4133: Use most efficient type of electric motors | $1,264 | $2,085 |
$1,264
19,050
kWh
|
|
| 03 | 2.4221: Install compressor air intakes in coolest locations | $1,829 | $300 |
$1,829
27,843
kWh
|
|
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $97 | $144 |
$97
1,465
kWh
|
|
| TOTAL RECOMMENDED | $24,167 | $4,689 |
$24,167
366,060
kWh
|
||
| TOTAL IMPLEMENTED | $22,806 | $2,460 |
$22,806
345,545
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs