| Assessment Year | 1992 |
|---|---|
| Principal Product | BOTTOM UNLOADERS |
| NAICS |
n/a
|
| SIC | 3523: Farm Machinery and Equipment |
| Sales Range | $5 M to 10M |
| # of Employees | 45 |
| Plant Area |
n/a
|
| Annual Production | 159
pieces
|
| Production Hrs. Annual | 4,000
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $17,253 | 242,966 |
kWh
|
$0.071 |
| Natural Gas | $7,617 | 1,535 |
MMBtu
|
$4.96 |
| Other Energy | $1,633 | 18 |
MMBtu
|
$90.72 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $6,663 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,306 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Other Energy Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4322: Use or replace with energy efficient substitutes | $3,760 | $14,000 | - |
$3,760
-
MMBtu
|
- | - | |
| 02 | 2.4133: Use most efficient type of electric motors | $582 | $4,765 |
$582
8,206
kWh
|
- | - | - | |
| 03 | 2.1332: Convert combustion equipment to burn natural gas | $1,535 | $1,200 | - |
$(-98.0)
-
MMBtu
|
$1,633
-
MMBtu
|
- | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $582 | $300 |
$582
8,206
kWh
|
- | - | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $38 | $500 |
$125
1,758
kWh
|
- | - | $(-87.0) | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $104 | $269 |
$104
1,465
kWh
|
- | - | - | |
| 07 | 2.4221: Install compressor air intakes in coolest locations | $62 | $200 |
$62
879
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $6,663 | $21,234 |
$1,455
20,514
kWh
|
$3,662
-
MMBtu
|
$1,633
-
MMBtu
|
$(-87.0) | ||
| TOTAL IMPLEMENTED | $1,306 | $5,834 |
$1,393
19,635
kWh
|
- | - | $(-87.0) | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Other Energy Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs