| Assessment Year | 1992 |
|---|---|
| Principal Product | ALUMINUM DIE CASTINGS |
| NAICS |
n/a
|
| SIC | 3365: Aluminum Foundries |
| Sales Range | $10 M to 50M |
| # of Employees | 160 |
| Plant Area |
n/a
|
| Annual Production | 15,000
ton
|
| Production Hrs. Annual | 7,200
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $420,630 | 7,838,511 |
kWh
|
$0.054 |
| Natural Gas | $310,623 | 228,048 |
MMBtu
|
$1.36 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $14,067 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $12,193 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $6,000 | $25,240 |
$6,000
111,372
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,840 | $579 |
$3,087
57,444
kWh
|
$(-247.0) | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,324 | $1,000 |
$3,324
60,082
kWh
|
- | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $1,874 | $1,000 |
$1,874
34,877
kWh
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $29 | $44 |
$29
586
kWh
|
- | |
| TOTAL RECOMMENDED | $14,067 | $27,863 |
$14,314
264,361
kWh
|
$(-247.0) | ||
| TOTAL IMPLEMENTED | $12,193 | $26,863 |
$12,440
229,484
kWh
|
$(-247.0) | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs