| Assessment Year | 1992 |
|---|---|
| Principal Product | DAIRY,BUTTER |
| NAICS |
n/a
|
| SIC | 2026: Fluid Milk |
| Sales Range | $10 M to 50M |
| # of Employees | 28 |
| Plant Area |
n/a
|
| Annual Production | 6,150,000
lb
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $163,126 | 2,435,815 |
kWh
|
$0.067 |
| Natural Gas | $250,865 | 107,073 |
MMBtu
|
$2.34 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $9,711 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $3,322 | $11,510 |
$3,322
49,531
kWh
|
- | - | |
| 02 | 2.2511: Insulate bare equipment | $2,439 | $2,439 | - |
$2,439
-
MMBtu
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,724 | $680 |
$2,034
30,481
kWh
|
- | $(-310.0) | |
| 04 | 2.2113: Repair or replace steam traps | $812 | $650 | - |
$812
-
MMBtu
|
- | |
| 05 | 2.4221: Install compressor air intakes in coolest locations | $689 | $250 |
$689
10,258
kWh
|
- | - | |
| 06 | 2.2511: Insulate bare equipment | $667 | $324 |
$667
9,965
kWh
|
- | - | |
| 07 | 2.2122: Install / repair insulation on condensate lines | $58 | $231 | - |
$58
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $9,711 | $16,084 |
$6,712
100,235
kWh
|
$3,309
-
MMBtu
|
$(-310.0) | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs