Assessment Year | 1992 |
---|---|
Principal Product | REFRACTORY BRICK |
NAICS |
n/a
|
SIC | 3297: Nonclay Refractories |
Sales Range | $10 M to 50M |
# of Employees | 160 |
Plant Area |
n/a
|
Annual Production | 38,000
ton
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $457,560 | 6,703,693 |
kWh
|
$0.068 |
Natural Gas | $702,842 | 264,768 |
MMBtu
|
$2.65 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $41,834 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,775 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $2,750 | $15,200 |
$2,750
41,618
kWh
|
- | - | |
02 | 2.6218: Turn off equipment when not in use | $12,216 | $320 |
$12,216
179,074
kWh
|
- | - | |
03 | 2.4239: Eliminate or reduce compressed air usage | $15,791 | $15,000 |
$15,791
231,536
kWh
|
- | - | |
04 | 2.3212: Optimize plant power factor | $8,052 | $6,780 |
$8,052
-
kWh
|
- | - | |
05 | 2.7261: Install timers and/or thermostats | $2,729 | $3,400 | - |
$2,756
-
MMBtu
|
$(-27.0) | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $296 | $800 |
$418
6,155
kWh
|
- | $(-122.0) | |
TOTAL RECOMMENDED | $41,834 | $41,500 |
$39,227
458,383
kWh
|
$2,756
-
MMBtu
|
$(-149.0) | ||
TOTAL IMPLEMENTED | $5,775 | $19,400 |
$3,168
47,773
kWh
|
$2,756
-
MMBtu
|
$(-149.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs