Assessment Year | 2017 |
---|---|
Principal Product | Photographic paper |
NAICS | 325992: Photographic Film, Paper, Plate, and Chemical Manufacturing |
SIC | 2679: Converted Paper and Paperboard Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 140 |
Plant Area |
350,000
ft2
|
Annual Production | 6,000
thousand feet
|
Production Hrs. Annual | 4,750
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $533,779 | 13,664,000 |
kWh
|
$0.039 |
Electricity Demand | $388,859 | 34,640 |
kW-mo/yr
|
$11.23 |
Natural Gas | $371,400 | 74,799 |
MMBtu
|
$4.97 |
TOTAL YEARLY COSTS | $1,294,038 | |||
RECOMMENDED SAVINGS* | $96,830 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $72,974 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.2444: Use hot process fluids to preheat incoming process fluids | $23,044 | $93,000 |
$4,434
113,400
kWh
|
$7,525
-
kW-mo/yr
|
$11,085
-
MMBtu
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,828 | $10,328 |
$1,075
27,489
kWh
|
$1,477
-
kW-mo/yr
|
- | $276 | |
03 | 2.7124: Make a practice of turning off lights when not needed | $118 | $50 |
$62
1,577
kWh
|
$44
-
kW-mo/yr
|
- | $12 | |
04 | 2.4239: Eliminate or reduce compressed air usage | $812 | $1,000 |
$474
12,113
kWh
|
$338
-
kW-mo/yr
|
- | - | |
05 | 2.4221: Install compressor air intakes in coolest locations | $685 | $2,000 |
$491
12,556
kWh
|
$194
-
kW-mo/yr
|
- | - | |
06 | 2.8114: Change rate schedules or other changes in utility service | $65,888 | $500 |
$65,888
-
kWh
|
- | - | - | |
07 | 2.4151: Develop a repair/replace policy | $3,455 | $11,302 |
$1,412
36,119
kWh
|
$2,043
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $96,830 | $118,180 |
$73,836
203,254
kWh
|
$11,621
-
kW-mo/yr
|
$11,085
-
MMBtu
|
$288 | ||
TOTAL IMPLEMENTED | $72,974 | $24,180 |
$68,928
77,741
kWh
|
$3,758
-
kW-mo/yr
|
- | $288 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs