Assessment Year | 2016 |
---|---|
Principal Product | Plastic injection molding |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 85 |
Plant Area |
82,000
ft2
|
Annual Production | 1,700,000
lb
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $174,024 | 3,298,800 |
kWh
|
$0.053 |
Electricity Demand | $64,323 | 7,378 |
kW-mo/yr
|
$8.72 |
Electricity Fees | $(-17,447.0) | - |
|
- |
TOTAL YEARLY COSTS | $220,900 | |||
RECOMMENDED SAVINGS* | $33,209 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $885 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $10,183 | $21,035 |
$7,467
141,151
kWh
|
$2,716
-
kW-mo/yr
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,714 | $26,550 |
$3,846
72,712
kWh
|
$1,868
-
kW-mo/yr
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $959 | $3,905 |
$959
18,146
kWh
|
- | - | - | |
04 | 2.7135: Install occupancy sensors | $1,083 | $1,785 |
$1,083
20,480
kWh
|
- | - | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $885 | $200 |
$1,247
23,580
kWh
|
$418
-
kW-mo/yr
|
$(-300.0) | $(-480.0) | |
06 | 2.4224: Upgrade controls on compressors | $13,915 | $20,000 |
$10,423
197,032
kWh
|
$3,492
-
kW-mo/yr
|
- | - | |
07 | 2.2511: Insulate bare equipment | $470 | $340 |
$470
8,899
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $33,209 | $73,815 |
$25,495
482,000
kWh
|
$8,494
-
kW-mo/yr
|
$(-300.0) | $(-480.0) | ||
TOTAL IMPLEMENTED | $885 | $200 |
$1,247
23,580
kWh
|
$418
-
kW-mo/yr
|
$(-300.0) | $(-480.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs